Plumbing Practice Test — Journeyman & Master Exam Prep

300 code-based practice questions covering DWV systems, water supply sizing, fixture units, venting methods, backflow prevention, and gas piping. Prepare for your IPC or UPC journeyman plumber exam with confidence.

300
Questions
10
Domains
25 free
To get started
Start Exam

Try your first 25 questions free. Continue with a paid plan.

Topics Covered

DWV Systems

Drain, waste, and vent pipe sizing, materials, and installation methods

Water Supply & Distribution

Pipe sizing, pressure calculations, and hot/cold water piping design

Fixture Unit Calculations

DFU and WSFU values, load calculations, and fixture count requirements

Venting Methods

Individual, common, wet, circuit, and island venting configurations

Water Heater Installation

Sizing, T&P valve requirements, expansion tanks, and safety controls

Backflow Prevention

Air gaps, backflow preventers, cross-connection control, and testing

Gas Piping

Pipe sizing, BTU calculations, materials, testing, and venting

Drainage Design

Slope requirements, cleanouts, interceptors, and storm drainage

Plumbing Math

Pipe offsets, volume calculations, grade, and measurement conversions

Code Regulations

IPC and UPC requirements, permits, inspections, and code compliance

Try 10 Sample Questions

Question 1 of 10
What is the minimum slope required for a 4-inch horizontal drain pipe per the IPC?
Answer: B

Per the IPC, horizontal drain pipes 3 inches in diameter and larger require a minimum slope of 1/8 inch per foot. Pipes smaller than 3 inches require 1/4 inch per foot. This slope ensures adequate flow velocity (minimum 2 feet per second) to carry solids through the pipe and prevent buildup and blockages.

Question 2 of 10
A water closet (toilet) has a drainage fixture unit (DFU) value of how many units per the IPC?
Answer: C

Per the IPC fixture unit table, a water closet (with a flush valve or tank) is assigned 4 drainage fixture units (DFU). This value is used to determine the required size of drain pipes, vent pipes, and building sewers. Understanding DFU values is fundamental to proper plumbing system design and sizing.

Question 3 of 10
What is the minimum size vent pipe that can be installed for a single water closet?
Answer: B

The minimum individual vent size for a water closet is 1-1/2 inches per code. The vent pipe must be at least one-half the diameter of the drain it serves (water closet drain is 3 inches minimum, half of which is 1-1/2 inches). Proper vent sizing ensures adequate air supply to maintain trap seals and prevent siphonage.

Question 4 of 10
At what temperature must the relief valve on a residential water heater be set to discharge?
Answer: C

The temperature and pressure (T&P) relief valve on a water heater must be rated to discharge at or below 210°F and/or 150 psi. These settings prevent the water heater from reaching conditions that could cause a catastrophic failure. The discharge pipe must terminate at a visible location within 6 inches of the floor or to an approved indirect waste receptor.

Question 5 of 10
What is the minimum air gap required between a faucet spout and the flood level rim of a lavatory?
Answer: A

The minimum air gap for a fixture is defined as 1 inch or twice the effective opening (diameter) of the supply pipe, whichever is greater. An air gap is the most reliable form of backflow prevention because it provides a complete physical separation between the potable water supply and a potential source of contamination.

Question 6 of 10
When installing a gas pipe run supplying 200,000 BTU/hr at a maximum of 100 feet equivalent length, what is the minimum pipe size for natural gas at 0.5 inches w.c. pressure drop?
Answer: C

Per the gas pipe sizing table for natural gas at 0.5 inches w.c. pressure drop with a specific gravity of 0.60, a 100-foot run at 200,000 BTU/hr requires a minimum 1-1/4 inch pipe. Gas pipe sizing depends on the total BTU demand, pipe length, allowable pressure drop, and the specific gravity of the gas. Undersizing results in insufficient gas pressure at the appliance.

Question 7 of 10
What fitting is prohibited for use in a drainage system to make a change of direction from horizontal to vertical?
Answer: D

Short-pattern 90-degree elbows (quarter bends) are prohibited in drainage systems for horizontal-to-vertical direction changes because they create an abrupt turn that can obstruct flow and cause blockages. Long-sweep elbows, combination wye and 1/8 bends, and sanitary tees are approved fittings that provide a gradual transition, maintaining proper flow characteristics in the drainage system.

Question 8 of 10
What is the maximum distance a P-trap can be located from the fixture it serves, measured from the trap weir to the vent opening?
Answer: C

The maximum trap-to-vent distance depends on the trap arm pipe diameter. For 1-1/2 inch pipe, the maximum distance is 6 feet; for 2-inch pipe, it is 8 feet; for 3-inch pipe, it is 12 feet. Exceeding these distances can cause the trap seal to be lost through siphonage because the vent cannot adequately equalize pressure in the drain line at excessive distances.

Question 9 of 10
A wet vent serves multiple fixtures. Which fixture is typically required to be the most upstream fixture on a wet-vented section?
Answer: C

In a wet-vented system per the IPC, the water closet is typically the most upstream (highest) fixture connection on the wet-vented section. The wet vent pipe serves as both a drain for one fixture and a vent for downstream fixtures. The wet vent must be sized to handle both the drainage and venting loads, and the water closet connection at the upper end ensures proper hydraulic function.

Question 10 of 10
When testing a new DWV system with an air test, what is the required test pressure and minimum hold time?
Answer: B

Per the IPC, when performing an air test on a DWV system, the system must be pressurized to 5 psi and must hold that pressure for a minimum of 15 minutes with no detectable pressure loss. The air test is an alternative to the water test and is commonly used when water testing is impractical. The low pressure prevents damage to trap seals and fittings.

Ready for the Full Exam?

Access all 300 plumbing practice questions with detailed explanations.

Start Exam

Frequently Asked Questions

How many plumbing practice questions are available?

We offer 300 plumbing practice questions based on the International Plumbing Code and Uniform Plumbing Code, covering topics needed for journeyman and master plumber licensing exams.

Is this plumbing practice test free?

Your first 25 questions are free. Continue beyond 25 questions with a paid plan.

What topics does the plumbing practice test cover?

The test covers DWV systems, water supply and distribution, fixture unit calculations, venting methods, water heater installation, backflow prevention, gas piping, drainage design, plumbing math, and code regulations.

Which plumbing code does this test follow?

Our questions are primarily based on the International Plumbing Code (IPC), which is adopted by most U.S. states. Many questions are also applicable to the Uniform Plumbing Code (UPC) used in western states. Check with your local jurisdiction for the applicable code edition.

Ready to Take the Real Exam?

Register for your Journeyman Plumber exam through Prometric, or grab the Plumber's Handbook.

Register for Exam View Study Guides